• Skip to content
  • Skip to footer

Nobel International

  • Company
  • Products
    • Solar water heaters
    • Water tanks for forced circulation systems
    • Buffer water tanks
    • Solar collectors
    • Electric water heaters
    • Heat Pumps
  • Downloads
  • News
  • Careers
  • Contact
  • English
  • Español
  • Français
  • Italiano
  • Deutsch
  • български

NOBEL Air Heat Pump R32

Home / Products / Heat Pumps / NOBEL Air Heat Pump R32
  • Nobel_HEAT-PUMP-R32
  • Nobel_HEAT-PUMP-R32

NOBEL R32 Monoblock DC Inverter Heat Pump is the newest air source heat pump that reaches A+++ energy efficiency.
It’s integrated with heating, Cooling, and DHW function.

AVAILABLE MODELS

NBL-HPM-NT-S006-V1
NBL-HPM-NT-S010-V1
NBL-HPM-NT-S014-V1
NBL-HPM-NT-S018-V1
NBL-HPM-NT-S010-V3
NBL-HPM-NT-S014-V3
NBL-HPM-NT-S018-V3
NBL-HPM-NT-S024-V3
Air Heat Pump R32

Thanks to the integrated heating / cooling / DHW function in the heat pump, the R32 HP is able to deliver the right temperature with great power. It gives users more options to get the perfect results they want, regardless of extreme cold / hot climates.

  • Overview
  • Technical features
  • Dimensions
  • Download Files
Air Source Heat Pump R32
Efficient heating and cooling and DWH perfomance

Nobel_heat_pump_item

R32 Full DC Inverter Heat Pump

NOBEL R32 heat pump adopts Panasonic DC inverter Compressor and Panasonic DC inverter fan. With this technology, users can enjoy a maximum level of comfort at the lowest costs. Freestanding features In the market is to save space and money. For sure.  The R32 Full DC Inverter heat pump will be the future trend.

 

 

 

 

 

 

 

Intelligent defrosting technology

Nobel_Heat-Pump_Intelligent-Defrosting-TechnologyNOBEL intelligent defrost control mode calculates the temperature difference and the accumulated working time of the compressor to judge the defrost condition of the evaporator. When the defrost condition is met, it will automatically enter the defrost mode.

Heating in low temp. of -30oC

Nobel_Heat-Pump_FanWith the use of a DC inverter Panasonic compressor and DC inverter controller, it can automatically increase the operating frequency according to the ambient temperature and greatly improve the heating capacity in a low-temperature environment.

Super Low Noise

Nobel-Heat-Pump-_Low-NoiseEquipped with the DC inverter brushless fans and designed based on aerodynamics, NOBEL DC inverter heat pumps adopt multiple noise reduction and sound insulation measures so that noise is reduced to a low level.

High Heating Efficiency

Nobel_Heat_Pump High Heating EfficiencyThe unit can operate at a high frequency to heat water mat a faster speed. When the temperature reaches the set temperature, it will operate at a low frequency withless energy consumed to maintain temperature.

Environmentally friendly

R32_icon 1R32 is environmentally friendly and has no combustion or exhaust gas emissions.

ERP A+++

A+++ERP A+++ R32 DC inverter heat pumps charge and recirculate more efficiently than DC inverter heat pumps of other refrigerants.

WIFI

WI-FIWith the WIFI online monitoring, customers will enjoy contactless support from our customer service center no matter where they are.

ModelNBL-HPM-NT-S006-V1NBL-HPM-NT-S010-V1NBL-HPM-NT-S014-V1NBL-HPM-NT-S018-V1NBL-HPM-NT-S010-V3 NBL-HPM-NT-S014-V3NBL-HPM-NT-S018-V3NBL-HPM-NT-S024-V3
Power supply220-240 V~/50 Hz220-240 V~/50 Hz Hz220-240 V~/50 Hz Hz220-240 V~/50 Hz Hz380~415 V/3/50 Hz380~415 V/3/50 Hz380~415 V/3/50 Hz380~415 V/3/50 Hz
Heating: Performance Condition: Outdoor air 7oC / 6oC, Inlet / Outlet water 30oC / 35oC
Heating capacity (kW)6.46(2.50~8.30)10.58(4.20~12.20)14.45(5.30~16.50)18.77(6.20~20.50)10.58(4.20~12.20)14.45(5.30~16.50)18.77(6.20~20.50)24.33(6.50~26.10)
Rated Power Input (kW)0.57-1.920.86-2.881.15-4.151.36-5.280.86-2.881.15-4.151.36-5.281.78-6.45
Input Current2.53-8.523.82-12.775.10-18.416.10-23.671.22-4.091.63-5.902.31-8.962.87-10.35
Heating: Performance Condition: Outdoor air 7oC / 6oC, Inlet / Outlet water 47oC / 55oC
Heating capacity (kW)2.30-7.623.85-11.204.90-15.106.30-19.903.85-11.204.90-15.106.30-19.906.90-26.10
Rated Power Input (kW)0.75-2.611.13-3.751.65-5.251.65-6.821.13-3.751.65-5.251.65-6.821.95-8.55
Input Current3.32-11.585.01-16.67.32-23.307.40-30.561.61-5.322.35-7.472.80-11.583.15-13.80
Cooling: Performance Condition: Outdoor air 35oC / 24oC, Inlet / Outlet water 12oC / 7oC
Cooling capacity (kW)1.80-7.102.60-10.304.50-13.505.50-17.502.60-10.304.50-13.505.50-17.505.20-20.30
Rated Power Input (kW)0.61-2.430.91-3.651.45-4.851.65-6.250.91-3.651.45-4.851.65-6.251.95-8.20
Input Current2.71-10.784.03-16.196.43-21.527.40-28.021.29-5.192.06-6.892.8-10.613.15-13.23
General data
ERP Level (Outlet water temp. at 35oC)/SCOPA+++/4.92A+++/4.55A+++/4.58A+++/4.61A+++/4.55A+++/4.58A+++/4.64A+++/4.58
ERP Level (Outlet water temp. at 55oC)/SCOPA++/3.37A++/3.41A++/3.39A++/3.41A++/3.41A++/3.39A++/3.42A++/3.42
Rated Input Power(kW)2.713.836.207.243.835.977.249.38
Rated Input Current(A)12.001727.5035.506.510.5013.2017.30
Refrigerant/WeightR32/1.25kgR32/1.8kgR32/2.8kgR32/3.5kgR32/1.8kgR32/2.8kgR32/3.5kgR32/3.5kg
Rated Water Flow(m³/h)1.11.752.523.21.752.523.24.12
Fan Motor TypeDC inverterDC inverterDC inverterDC inverterDC inverterDC inverterDC inverterDC inverter
CompressorPanasonic/DC Inverter/Rotary/EVIPanasonic/DC Inverter/Rotary/EVIPanasonic/DC Inverter/Rotary/EVIPanasonic/DC Inverter/Rotary/EVIPanasonic/DC Inverter/Rotary/EVIPanasonic/DC Inverter/Rotary/EVIPanasonic/DC Inverter/Rotary/EVIPanasonic/DC Inverter/Rotary/EVI
Circulation PumpInverter Type/Built-inInverter Type/Built-inInverter Type/Built-inInverter Type/Built-inInverter Type/Built-inInverter Type/Built-inInverter Type/Built-inInverter Type/Built-in
IP ClassIPX4IPX4IPX4IPX4IPX4IPX4IPX4IPX4
Noise Level(dB(A)5051555651525458
Max Outlet Water Temperature(oC)6060606060606060
Water Piping ConnectionsDN 25 (1’’)DN 25 (1’’)DN 32 (1-1/4’’)DN 40 (1.5’’)DN 25 (1’’)DN 32 (1-1/4’’)DN 40 (1.5’’)DN 40 (1.5’’)
Pressure Drop at Rating Water Flow(kPa)2527303027303232
Operating Temperature Range (Heating Mode) (oC)-25~45-25~45-25~45-25~45-30~45-30~45-30~45-30~45
Operating Temperature Range (Cooling Mode) (oC)16~4516~4516~4516~4516~4516~4516~4516~45
Net Dimensions (L*D*H)(mm)1100*445*8501110*445*8501110*480*8501110*480*8501100*445*8501110*475*8501110*445*14501110*445*1450
Net Weight (kg)102109125151102124151160
ModelPacked Dimensions (mm)
NBL-HPM-NT-S006-V11160*530*1010
NBL-HPM-NT-S010-V11160*530*1010
NBL-HPM-NT-S010-V31160*530*1010
NBL-HPM-NT-S014-V11160*565*1010
NBL-HPM-NT-S014-V31160*565*1010

Footer

INFORMATION

  • Energy labeling
  • Our solar systems
  • Environment & Energy
  • Frequently Asked Questions
  • Company
  • Contact
  • Careers
  • News
  • Privacy Policy

PRODUCTS

  • NOBEL Hyperion
  • NOBEL Apollon
  • NOBEL Aelios
  • Solar collectors
  • Water tanks for forced circulation systems
  • Electric water heaters
  • Downloads

Newsletter

SOCIAL

Copyright © 2025 Nobel. All rights reserved.