• Skip to content
  • Skip to footer

Nobel International

  • Company
  • Products
    • Solar water heaters
    • Water tanks for forced circulation systems
    • Buffer water tanks
    • Solar collectors
    • Electric water heaters
    • Heat Pumps
  • Downloads
  • News
  • Careers
  • Contact
  • English
  • Español
  • Français
  • Italiano
  • Deutsch
  • български

Forced Circulation Tanks for Heat Pump

Home / Products / Water tanks for forced circulation systems / Forced Circulation Tanks for Heat Pump
  • Nobel_FC-HP_TANKS
  • Nobel_FC-HP_TANKS

Available in various sizes, the Forced circulation tanks  for Heat pump with one or two heat exchanger serve numerous applications. They are mostly encountered in cases of many collectors, where large quantities of hot water are required. Moreover, such systems in smaller capacities often replace solar water heaters mainly for technical or aesthetic reasons.

AVAILABLE MODELS

TYPEWith 1 heat exchangerWith 2 heat exchangers
160ltYESYES
200ltYESYES
300ltYESYES
400ltYESYES
500ltYESYES
800lt YESYES
1000ltYESYES
  • Overview
  • Technical features
  • Dimensions
  • Download Files
  • Water storage tank: cold rolled steel with a double internal layer of enamel, baked at 860°C according to DIN 4753.
    The enameling is done in our own high tech industrial facilities. The boilers are checked individually upon
    exit from the enameling unit, assuring the top quality of the enamel.
  • Heat exchangers for the transfer of thermal energy:
    – Internal double coil type heavy duty steel (type Tubo) integrated in the lower part of the tank, for the
    connection to the Heat Pump.
    – Optional internal double coil type heavy duty steel (type Tubo) integrated in the upper part of the tank, for
    the connection of the secondary heating source.
  • Thermal insulation: which minimises heat losses, maintaining the hot water temperature:
    – Expanded ecologically safe polyurethane for up to 500lt capacity types.
    – Flexible removable insulation of 70mm thickness , for the 800lt and 1000lt capacities.
  • External housing of special PVC for excellent aesthetics.
  • Cathode protection with a periodically replaceable magnesium anode for effective internal protection against
    corrosion and mineral deposits which are caused by electrolytic reactions.
  • Electrical components:
    – Heating element rated according to the local regulations of the country of destination*
    – Automatically regulated thermostat with bipolar protection and auxiliary fuse*
NOBEL FC HP 1 - With 1 heat exchanger
MODEL1602003004005008001000
TOTAL CAPACITY (EN 12897) lt150181276368429750933
NET WEIGHT kg87105151179211277342
INSULATIONmm50505050507070
HEAT EXCHANGER SURFACE (S1 – LOWER HE)m² 1,802,623,774,766,006,558,20
HEAT EXCHANGER CAPACITY (S1) lt9131823294354
HEAT EXCHANGER OUTPUT (60-80°C) (S1)kW436390114144157197
HEAT EXCHANGER CONTINUOUS FLOW RATE (60-80°C) (S1)L/h1059154522232807353838634836
ΗΕΑΤ LOSSES ΔΤ 45KkWh/24h1.41.51.72.22.53.23.5
ENERGY EFFICIENCY CLASSBBBCCCC
Heat Exchanger Pressure drop C1mbar2856117210332424612
MAXIMUM OPERATIONAL TEMPERATURE°C95959595959595
RATED PRESSUREbar101010101088
RATED PRESSURE OF THE HEAT EXCHANGERbar6666666
NOBEL FC HP 2 - With 2 heat exchangers
MODEL 2003004005008001000
TOTAL CAPACITY (EN 12897)lt184272369431746919
NET WEIGHT kg 102164177212294346
INSULATIONmm 505050507070
HEAT EXCHANGER SURFACE (S1 – LOWER HE)m² 0,641,141,511,512,443,66
HEAT EXCHANGER SURFACE (S2 – UPPER HE)m² 1,653,123,064,214,546,18
HEAT EXCHANGER CAPACITY (S1) lt 36771624
HEAT EXCHANGER CAPACITY (S2) lt 81515213040
HEAT EXCHANGER OUTPUT (60-80°C) (S1)kW152736365988
HEAT EXCHANGER OUTPUT (60-80°C) (S2)kW407573101109148
HEAT EXCHANGER CONTINUOUS FLOW RATE (60-80°C) (S1)L/h37767289089014392158
HEAT EXCHANGER CONTINUOUS FLOW RATE (60-80°C) (S2)L/h97318401805248326773644
ΗΕΑΤ LOSSES ΔΤ 45KkWh/24h1.51.72.22.53.23.5
ENERGY EFFICIENCY CLASSBBCCCC
Heat Exchanger Pressure drop C1mbar923626286187
Heat Exchanger Pressure drop C2mbar4496154229262495
MAXIMUM OPERATIONAL TEMPERATURE°C959595959595
RATED PRESSUREbar1010101088
RATED PRESSURE OF THE HEAT EXCHANGERbar666666
TYPE HTD Ext.
FC1 160 1035600
FC1 200 1230 600
FC2 200 1230 600
FC1 300 1760600
FC2 300 1760600
FC1 400 1655 700
FC2 400 1655 700
FC1 500 1900 700
FC2 500 1900 700
FC1 800 1770990
FC2 800 1770990
FC1 1000 2100990
FC2 1000 2100990

Dimensions in mm

Techical manual - Brochures
Icon

Technical manual Forced circulation tank for Heat pump

1 file(s) 4 MB
Download
Icon

Brochure Forced circulation tank for Heat pump

1 file(s) 4 MB
Download
Product Fiches
Model 1 Heat Exchanger 2 Heat Exchangers
160lt
Icon

PF - BOFC1-160 HP (ENG)

1 file(s) 40.67 KB
Download
–
200lt
Icon

PF - BOFC1-200 HP (ENG)

1 file(s) 31.73 KB
Download
Icon

PF - BOFC2-200 HP (ENG)

1 file(s) 95.82 KB
Download
300lt
Icon

PF - BOFC1-300 HP (ENG)

1 file(s) 89.43 KB
Download
Icon

PF - BOFC2-300 HP (ENG)

1 file(s) 97.03 KB
Download
400lt
Icon

PF - BOFC1-400 HP (ENG)

1 file(s) 93.42 KB
Download
Icon

PF - BOFC2-400 HP (ENG)

1 file(s) 95.75 KB
Download
500lt
Icon

PF - BOFC1-500 HP (ENG)

1 file(s) 94.01 KB
Download
Icon

PF - BOFC2-500 HP (ENG)

1 file(s) 95.55 KB
Download
800lt
Icon

PF - BOFC1-800 HP (ENG)

1 file(s) 94.19 KB
Download
Icon

PF - BOFC2-800 HP (ENG)

1 file(s) 95.05 KB
Download
1000lt
Icon

PF - BOFC1-1000 HP (ENG)

1 file(s) 93.64 KB
Download
Icon

PF - BOFC2-1000 HP (ENG)

1 file(s) 94.90 KB
Download
Declarations of Conformity (EU)
Model 1 Heat Exchanger 2 Heat Exchangers
160lt
Icon

EU - BOILER FC1_160 HP GLASS

1 file(s) 142.04 KB
Download
–
200lt
Icon

EU - BOILER FC1_200 HP GLASS

1 file(s) 142.05 KB
Download
Icon

EU - BOILER FC2_200 HP GLASS

1 file(s) 141.90 KB
Download
300lt
Icon

EU - BOILER FC1_300 HP GLASS

1 file(s) 142.05 KB
Download
Icon

EU - BOILER FC2_300 HP GLASS

1 file(s) 141.89 KB
Download
400lt
Icon

EU - BOILER FC1_400 HP GLASS

1 file(s) 142.05 KB
Download
Icon

EU - BOILER FC2_400 HP GLASS

1 file(s) 141.88 KB
Download
500lt
Icon

EU - BOILER FC1_500 HP GLASS

1 file(s) 142.05 KB
Download
Icon

EU - BOILER FC2_500 HP GLASS

1 file(s) 141.85 KB
Download
800lt
Icon

EU - BOILER FC1_800 HP GLASS

1 file(s) 142.05 KB
Download
Icon

EU - BOILER FC2_800 HP GLASS

1 file(s) 141.92 KB
Download
1000lt
Icon

EU - BOILER FC1_1000 HP GLASS

1 file(s) 142.05 KB
Download
Icon

EU - BOILER FC2_1000 HP GLASS

1 file(s) 141.88 KB
Download
Energy labels
Model 1 Heat Exchanger 2 Heat Exchangers
160lt
Icon

EL - LABEL BO_FC1-160_HEAT PUMP

1 file(s) 24.92 KB
Download
–
200lt
Icon

EL - LABEL BO_FC1-200_HEAT PUMP

1 file(s) 24.61 KB
Download
Icon

EL - LABEL BO_FC2-200 HEAT PUMP

1 file(s) 24.61 KB
Download
300lt
Icon

EL - LABEL BO_FC1-300 HEAT PUMP

1 file(s) 24.85 KB
Download
Icon

EL - LABEL BO_FC2-300 HEAT PUMP

1 file(s) 24.85 KB
Download
400lt
Icon

EL - LABEL BO_FC1-400_HEAT PUMP

1 file(s) 24.69 KB
Download
Icon

EL - LABEL BO_FC2-400 HEAT PUMP

1 file(s) 24.95 KB
Download
500lt
Icon

EL - LABEL BO_FC1-500_HEAT PUMP

1 file(s) 24.44 KB
Download
Icon

EL - LABEL BO_FC2-500_HEAT PUMP

1 file(s) 24.95 KB
Download
800lt
Icon

EL - LABEL BO_FC1-800_HEAT PUMP

1 file(s) 24.36 KB
Download
Icon

EL - LABEL BO_FC2-800_HEAT PUMP

1 file(s) 24.84 KB
Download
1000lt
Icon

EL - LABEL BO_FC1-1000_HEAT PUMP

1 file(s) 24.95 KB
Download
Icon

EL - LABEL BO_FC2-1000 HEAT PUMP

1 file(s) 24.95 KB
Download

Footer

INFORMATION

  • Energy labeling
  • Our solar systems
  • Environment & Energy
  • Frequently Asked Questions
  • Company
  • Contact
  • Careers
  • News
  • Privacy Policy

PRODUCTS

  • NOBEL Hyperion
  • NOBEL Apollon
  • NOBEL Aelios
  • Solar collectors
  • Water tanks for forced circulation systems
  • Electric water heaters
  • Downloads

Newsletter

SOCIAL

Copyright © 2026 Nobel. All rights reserved.